The use of Pulse Inversion Harmonic Imaging on a 2D convex probe can be another 

alternative to the transvaginal probe, apart from the limitations of transvaginal 

probes in the field, with the 2D convex probe the patient is comfortable when being 

examined with good ultrasound results. In this study, ultrasound images of first 

trimester pregnancy with the implementation of Pulse Inversion Harmonic Imaging 

Upgrade on the 2D convex transducer and without Pulse Inversion Harmonic 

Imaging on the transvaginal transducer. The image results on the 2D convex 

transducer are clearly visible using Pulse Inversion Harmonic Imaging with 

frequency, gain and depth settings. The image results of the 2D convex transducer 

with Pulse Inversion Harmonic Imaging upgrade are clearly visible at the wall 

boundary, clearly visible at the fetal object, and clearly visible at the yolk sac wall 

boundary. Comparative analysis between the 2D convex transducer image with 

upgraded Pulse Inversion Harmonic Imaging and the transvaginal transducer image 

without Pulse Inversion Harmonic Imaging showed no significant differences. 2D 

transabdominal convex ultrasound examination with Pulse Inversion Harmonic 

Imaging Upgrade can be used for pregnancy examinations in first trimester pregnant 

women with normal weight, because the resulting image results are not significantly 

different from transvaginal examinations without Pulse Inversion Harmonic 

Imaging.


Informasi Detail

Pernyataan Tanggungjawab
DIAH RUSITA
Pengarang
DIAH RUSITA - Pengarang Utama
Donny Kristanto M - First Advisor
Agung Nugroho Setiawan - Second Advisor
Yeti Kartikasari - First Examiner
Donny Kristanto M - Second Examiner
Agung Nugroho Setiawan - Third Examiner
Dwi Rochmayanti - Chief Examiner
NIM
P1337430421034
Bahasa
English
Deskripsi Fisik
XCIX, 99 page; Tidak ada ilustrasi: 33cm
Dilihat sebanyak
473
Penerbit T. Imaging Diagnostik Magister Terapan Kesehatan : Semarang.,
Edisi
Subjek
Klasifikasi
NONE

Lampiran Berkas

Citation
DIAH RUSITA. (2023).IMPLEMENTASI PULSE INVERSION HARMONIC IMAGING PADA TRANSDUCER CONVEX 2D TERHADAP INFORMASI ANATOMI CITRA USG KEHAMILAN TRIMESTER PERTAMA().Semarang:T. Imaging Diagnostik Magister Terapan Kesehatan

DIAH RUSITA.IMPLEMENTASI PULSE INVERSION HARMONIC IMAGING PADA TRANSDUCER CONVEX 2D TERHADAP INFORMASI ANATOMI CITRA USG KEHAMILAN TRIMESTER PERTAMA().Semarang:T. Imaging Diagnostik Magister Terapan Kesehatan,2023.Tesis

DIAH RUSITA.IMPLEMENTASI PULSE INVERSION HARMONIC IMAGING PADA TRANSDUCER CONVEX 2D TERHADAP INFORMASI ANATOMI CITRA USG KEHAMILAN TRIMESTER PERTAMA().Semarang:T. Imaging Diagnostik Magister Terapan Kesehatan,2023.Tesis

DIAH RUSITA.IMPLEMENTASI PULSE INVERSION HARMONIC IMAGING PADA TRANSDUCER CONVEX 2D TERHADAP INFORMASI ANATOMI CITRA USG KEHAMILAN TRIMESTER PERTAMA().Semarang:T. Imaging Diagnostik Magister Terapan Kesehatan,2023.Tesis



Dirujuk oleh 0 dokumen