Image of ANALISIS PERBEDAAN INFORMASI ANATOMI PADA CITRA DENGAN VARIASI TIME ECHO (TE) PEMERIKSAAN PHASE CONTRAST MAGNETIC RESONANCE VENOGRAPHY OTAK

Skripsi D IV

ANALISIS PERBEDAAN INFORMASI ANATOMI PADA CITRA DENGAN VARIASI TIME ECHO (TE) PEMERIKSAAN PHASE CONTRAST MAGNETIC RESONANCE VENOGRAPHY OTAK

XML

Magnetic Resonance Venography (MRV) is an MRI imaging technique to visualize venous drainage. A good sequence for brain MRV examination is a 3D Phase Contrast (3D-PC) sequence of GRE coherent techniques with T2 * weighted image results. One parameter influencing the contrast of T2 * weighting images is Time Echo (TE). TE is the time to apply the radiofrequency (RF) pulse to the peak of the signal induced in the coil and measured in milliseconds. This study aims to determine the differences in anatomical image information on PC-MRV sequence sequences and optimal TE values in the PC-MRV brain sequence.
This type of research is a quantitative experimental approach, conducted in March to April 2019 in Tarakan Hospital, Central Jakarta. Research by conducting TE variations of 7.6 ms, 15 ms and 22.5 ms in the PC-MRV sequence of the brain against 10 volunteers. Voluntary criterias are cooperative adult humans aged 17-30 years and do not have a history of abnormalities in the intracranial vein. The results of the images were assessed by 3 respondent Radiologists, including superior Sagittal Sinus, Transverse Sinus, Sigmoid Sinus, Galen Veins, Basal Veins and Jugular Veins. Then the Kappa test was carried out followed by the Frequency test, then the Friedman test to find the highest mean rank and the Post Hoc test the Wilcoxon test method was different.
The results showed that there were differences in intracranial vein anatomical information on MRV PC-MRV sequence head with a variation of three TE values and p-value 0.005 and 0,007 (p


Informasi Detail

Pernyataan Tanggungjawab
dr. Maya Nuriya Widyasari, Sp.Rad (K) dan Siti Masrochah, S.Si, M.Kes
Pengarang
NURILMA ANGGID KUSUMASARI - Pengarang Utama
NIM
P1337430215073
Bahasa
Indonesia
Deskripsi Fisik
XV + 99 hlm
Dilihat sebanyak
742
Penerbit PRODI DIV TEKNIK RADIOLOGI : Semarang.,
Edisi
Subjek
Klasifikasi

Lampiran Berkas

Citation
NURILMA ANGGID KUSUMASARI. (2019).ANALISIS PERBEDAAN INFORMASI ANATOMI PADA CITRA DENGAN VARIASI TIME ECHO (TE) PEMERIKSAAN PHASE CONTRAST MAGNETIC RESONANCE VENOGRAPHY OTAK().Semarang:PRODI DIV TEKNIK RADIOLOGI

NURILMA ANGGID KUSUMASARI.ANALISIS PERBEDAAN INFORMASI ANATOMI PADA CITRA DENGAN VARIASI TIME ECHO (TE) PEMERIKSAAN PHASE CONTRAST MAGNETIC RESONANCE VENOGRAPHY OTAK().Semarang:PRODI DIV TEKNIK RADIOLOGI,2019.Skripsi D IV

NURILMA ANGGID KUSUMASARI.ANALISIS PERBEDAAN INFORMASI ANATOMI PADA CITRA DENGAN VARIASI TIME ECHO (TE) PEMERIKSAAN PHASE CONTRAST MAGNETIC RESONANCE VENOGRAPHY OTAK().Semarang:PRODI DIV TEKNIK RADIOLOGI,2019.Skripsi D IV

NURILMA ANGGID KUSUMASARI.ANALISIS PERBEDAAN INFORMASI ANATOMI PADA CITRA DENGAN VARIASI TIME ECHO (TE) PEMERIKSAAN PHASE CONTRAST MAGNETIC RESONANCE VENOGRAPHY OTAK().Semarang:PRODI DIV TEKNIK RADIOLOGI,2019.Skripsi D IV



Dirujuk oleh 0 dokumen