Detail Cantuman

Image of EFFECT OF RECEIVE BANDWIDTH’S VARIATION TO SIGNAL TO NOISE RATIO
(SNR) AND CONTRAST TO NOISE RATIO (CNR) ON MRI EXAMINATION OF
CERVICAL WITH T2 WEIGHTED FAST SPIN ECHO SEQUENC HERNIA NUCKLEUS
PULPOSUS (HNP) CASE

Skripsi D IV

EFFECT OF RECEIVE BANDWIDTH’S VARIATION TO SIGNAL TO NOISE RATIO (SNR) AND CONTRAST TO NOISE RATIO (CNR) ON MRI EXAMINATION OF CERVICAL WITH T2 WEIGHTED FAST SPIN ECHO SEQUENC HERNIA NUCKLEUS PULPOSUS (HNP) CASE

XML

Background : The received bandwidth parameter is a parameter that can affect the value of SNR and CNR. The use of bandwidth value on
the MRI 1.5 Tesla for cervical MRI examination with T2 Weighted Fast Spin Echo sequence axial used a value of 27.87Hz/px. By doing the
variation of bandwidth, the quality of SNR and CNR image is different. The purpose of this study is to determine the effect of bandwidth
variation on SNR and CNR. To know the optimal value of receive bandwidth variation on cervical MRI examination with T2 Weighted Fast
Spin Echo sequence in Herniated Nuckleus Pulposus (HNP) case.
Methods : This type of research is qualitative research with experimental approach. This study was conducted using MRI GE 1.5 Tesla at
Bethesda Hospital Yogyakarta. Data in the form of 10 images of cervical MRI T2 FSE axial slice of 10 patients with 3 received bandwidth
variation (20.83Hz / px, 27.87Hz / px and 31.25Hz / px). To determine SNR and CNR values, Region of Interest (ROI) with size 1mm 2 were
placed on Discus Intervertebralis, Cerebrospinal Fluid, Spinal Cord and Ligament Flavum. And to get the average value of the signal then the
averageof signal was divided by the standard deviation from the background. The analysis was done by linear regression test and friedman
mean rank test.
Results : The result of research shows that there is influence between receive bandwidth variation on SNR and CNR cervical. The value of
20,83Hz/px receive bandwidth variation in cervical MRI examination with T2 Weighted Fast Spin Echo sequence result in optimal SNR and
CNR value.
Conclusion : There was the effect of the receive bandwidth of the SNR and CNR on MRI cervical sequences T2WI FSE axial. Receive
Bandwidth optimum value in MRI cervical T2WI FSE axial is 20,83Hz/px.


Informasi Detail

Pernyataan Tanggungjawab
agus Abimanyu, S.Si, M.Pd dan Darmini,S.SI, M.Kes
Pengarang
MUHAMMAD RAIZAL RAIS - Pengarang Utama
NIM
P1337430214031
Bahasa
Indonesia
Deskripsi Fisik
Xv + 82 hlm.; Bibl.; Ils.; 21 cm.
Dilihat sebanyak
771
Penerbit Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG : Semarang.,
Edisi
2018
Subjek
Klasifikasi
081

Lampiran Berkas

Citation
MUHAMMAD RAIZAL RAIS. (2018).EFFECT OF RECEIVE BANDWIDTH’S VARIATION TO SIGNAL TO NOISE RATIO (SNR) AND CONTRAST TO NOISE RATIO (CNR) ON MRI EXAMINATION OF CERVICAL WITH T2 WEIGHTED FAST SPIN ECHO SEQUENC HERNIA NUCKLEUS PULPOSUS (HNP) CASE(2018).Semarang:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG

MUHAMMAD RAIZAL RAIS.EFFECT OF RECEIVE BANDWIDTH’S VARIATION TO SIGNAL TO NOISE RATIO (SNR) AND CONTRAST TO NOISE RATIO (CNR) ON MRI EXAMINATION OF CERVICAL WITH T2 WEIGHTED FAST SPIN ECHO SEQUENC HERNIA NUCKLEUS PULPOSUS (HNP) CASE(2018).Semarang:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2018.Skripsi D IV

MUHAMMAD RAIZAL RAIS.EFFECT OF RECEIVE BANDWIDTH’S VARIATION TO SIGNAL TO NOISE RATIO (SNR) AND CONTRAST TO NOISE RATIO (CNR) ON MRI EXAMINATION OF CERVICAL WITH T2 WEIGHTED FAST SPIN ECHO SEQUENC HERNIA NUCKLEUS PULPOSUS (HNP) CASE(2018).Semarang:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2018.Skripsi D IV

MUHAMMAD RAIZAL RAIS.EFFECT OF RECEIVE BANDWIDTH’S VARIATION TO SIGNAL TO NOISE RATIO (SNR) AND CONTRAST TO NOISE RATIO (CNR) ON MRI EXAMINATION OF CERVICAL WITH T2 WEIGHTED FAST SPIN ECHO SEQUENC HERNIA NUCKLEUS PULPOSUS (HNP) CASE(2018).Semarang:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2018.Skripsi D IV



Dirujuk oleh 0 dokumen