Background : Cervical cancer is the second most common type of cancer worldwide, it is reaching 15% among all kind of cancer which happen in women. There are several ways in order to diagnose cervical cancer,one of them is MRI examination. One of the MRI sequence which can perform the pathology of cervical cancer is Diffusion Weighted Image. The aim of this research is to find out the anatomical differences between axial slice image of Pelvic MRI which is using DWI sequence with the variation of b value in the case of cervical cancer, and also to reveal the optimal b value to obtain the image of Pelvic MRI which is using DWI sequence in the case of cervical cancer.
Methods : The method of this research is experimental with the comparison of static groups. This research is done in Dr. Soetomo hospital, Surabaya. Data is 30 images of axial DWI Pelvic MRI from 10 patients in the case of cervical cancer with 3 different variation of b value, which are 600 s/mm2, 800 s/mm2, and 1000 s/mm2. Assessment of information image data done by 2 respondents. Analysing process done with Friedman test.
Results : The result showed that there are differences of image information between axial Pelvic MRI which is using DWI sequence with the variation of b value in the case of cervical cancer with the significant p value


Informasi Detail

Pernyataan Tanggungjawab
Rini Indrati, S.Si. M.Kes; dr Widiana Ferriastuti, Sp.Rad(K)
Pengarang
DISTYARINI PRIMADITA - Pengarang Utama
Rini Indrati - Pengarang Tambahan
Widiana Ferriastuti - Pengarang Tambahan
NIM
P1337430216149
Bahasa
English
Deskripsi Fisik
xv; 64 hal; 28cm
Dilihat sebanyak
620
Penerbit Jurusan Teknik Raiodiagnostik dan Radioerapi : Semarang.,
Edisi
Subjek
Klasifikasi
081

Lampiran Berkas

Citation
DISTYARINI PRIMADITA. (2017).DIFFERENCE OF THE IMAGE INFORMATION AXIAL PELVIC MRI USING DIFUSSION WEIGHTED IMAGE SEQUENCE WITH THE VARIATION OF B VALUE IN THE CASE OF CERVICAL CANCER().Semarang:Jurusan Teknik Raiodiagnostik dan Radioerapi

DISTYARINI PRIMADITA.DIFFERENCE OF THE IMAGE INFORMATION AXIAL PELVIC MRI USING DIFUSSION WEIGHTED IMAGE SEQUENCE WITH THE VARIATION OF B VALUE IN THE CASE OF CERVICAL CANCER().Semarang:Jurusan Teknik Raiodiagnostik dan Radioerapi,2017.Skripsi D IV

DISTYARINI PRIMADITA.DIFFERENCE OF THE IMAGE INFORMATION AXIAL PELVIC MRI USING DIFUSSION WEIGHTED IMAGE SEQUENCE WITH THE VARIATION OF B VALUE IN THE CASE OF CERVICAL CANCER().Semarang:Jurusan Teknik Raiodiagnostik dan Radioerapi,2017.Skripsi D IV

DISTYARINI PRIMADITA.DIFFERENCE OF THE IMAGE INFORMATION AXIAL PELVIC MRI USING DIFUSSION WEIGHTED IMAGE SEQUENCE WITH THE VARIATION OF B VALUE IN THE CASE OF CERVICAL CANCER().Semarang:Jurusan Teknik Raiodiagnostik dan Radioerapi,2017.Skripsi D IV