Background: The settings for Window Width and Window Level are used differently. On Hitachi 16 Slice there is a standard setting for soft tissue Pelvis is with Window Width 350 and Window Level 30 while for bone Pelvis is with Window Width 1260 Background: The settings for Window Width and Window Level are used differently. On Hitachi 16 Slice there is a standard setting for soft tissue Pelvis is with Window Width 350 and Window Level 30 while for bone Pelvis is with Window Width 1260 and Window Level 351. On CT Scan Pelvis examination, there are several radiographer using Window Width 300 settings and Window Level 60 for Pelvis soft tissue. The purpose of this research is to know the difference of anatomical information and the use of Window Width and Window Level better in generating anatomical information of pelvic CT scan in case of ovarian cancer.
Method: type of research conducted in the writing of scientific papers is quantitative research using an experimental approach. Data collection was performed on 10 patients suspected of ovarian cancer, then adjusted variation window width and window level. The results of the window width and window level adjustments were then evaluated by two observers to obtain anatomical CT CT scan of ovarian cancer and then analyzed by using Friedman Test from spss version 16.0.
Result: The result of the research resulted the difference of Window Width and Window Level was assessed from p value


Informasi Detail

Pernyataan Tanggungjawab
YULIA WARDAH
Pengarang
YULIA WARDAH - Pengarang Utama
Rasyid - First Advisor
DARMINI - Second Advisor
BAGUS ABIMANYU - First Examiner
LUTHFI RUSYADI - Second Examiner
NIM
P1337430216137
Bahasa
Indonesia
Deskripsi Fisik
XIII, 59 HLM, 29 CM
Dilihat sebanyak
1079
Penerbit Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG : POLTEKKES KEMENKES SEMARANG.,
Edisi
Subjek
Klasifikasi
081

Lampiran Berkas

Citation
YULIA WARDAH. ().ANALISA VARIASI WINDOW WIDTH DAN WINDOW LEVEL PADA INFORMASI ANATOMIS CT SCAN PELVIS DENGAN KASUS KANKER OVARIUM MENGGUNAKAN PESAWAT HITACHI 16 SLICE DI RSU dr. SOETOMO SURABAYA().POLTEKKES KEMENKES SEMARANG:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG

YULIA WARDAH.ANALISA VARIASI WINDOW WIDTH DAN WINDOW LEVEL PADA INFORMASI ANATOMIS CT SCAN PELVIS DENGAN KASUS KANKER OVARIUM MENGGUNAKAN PESAWAT HITACHI 16 SLICE DI RSU dr. SOETOMO SURABAYA().POLTEKKES KEMENKES SEMARANG:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,.Skripsi D IV

YULIA WARDAH.ANALISA VARIASI WINDOW WIDTH DAN WINDOW LEVEL PADA INFORMASI ANATOMIS CT SCAN PELVIS DENGAN KASUS KANKER OVARIUM MENGGUNAKAN PESAWAT HITACHI 16 SLICE DI RSU dr. SOETOMO SURABAYA().POLTEKKES KEMENKES SEMARANG:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,.Skripsi D IV

YULIA WARDAH.ANALISA VARIASI WINDOW WIDTH DAN WINDOW LEVEL PADA INFORMASI ANATOMIS CT SCAN PELVIS DENGAN KASUS KANKER OVARIUM MENGGUNAKAN PESAWAT HITACHI 16 SLICE DI RSU dr. SOETOMO SURABAYA().POLTEKKES KEMENKES SEMARANG:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,.Skripsi D IV



Dirujuk oleh 0 dokumen