Detail Cantuman

Image of Analisis Informasi Citra MRI Genu Potongan Aksial Antara Sekuen SHORT TAU INVERSION RECOVERY (STIR) dan Sekuen T2-Spectral Attenuation Inversion Recovery (T2-SPAIR)

Jurnal Ilmiah

Analisis Informasi Citra MRI Genu Potongan Aksial Antara Sekuen SHORT TAU INVERSION RECOVERY (STIR) dan Sekuen T2-Spectral Attenuation Inversion Recovery (T2-SPAIR)

XML

Backgrounds: Genu MRI examination, according to Moeller (2003) and Westbrook (2008), was done by one fat supression
technique in every slice. Radiology Installation of PAU dr.S.Hardjolukito Yogyakarta Hospital used two types of fat suppression technique
those are STIR and T2-SPAIR. This study aims to find out the image differences between STIR and T2-SPAIR and to determine the fat
suppresion technique that produces better image information of axial genu MR imaging.
Methods: This research was a quantitative research with an experimental approach. Subjects of this study was image of axial genu MRI
examination between STIR and T2- SPAIR in Radiology Installation of PAU dr.S.Hardjolukito Yogyakarta Hospital. The axial genu MR
imaging STIR and T2-SPAIR assessed by three radiology phisicians using questioner. Data were statistically analyzed using Wilcoxon Sign
Test.
Results: The results showed a significant difference in all categories of assessment criteria between STIR and T2-SPAIR. In this study, the
T2-SPAIR fat suppression technique produced better image information than STIR, whereas T2-SPAIR fat suppress signals was stronger than
STIR.
Conclusion: T2-SPAIR fat suppress signal was stronger than STIR that showed better image information and shorter time scanning


Informasi Detail

Pernyataan Tanggungjawab
Pengarang
Sri Mulyati - Pengarang Utama
Thuthit Dwi Astuti - Pengarang Tambahan
Emi Murniati - Pengarang Tambahan
NIM
Bahasa
Indonesia
Deskripsi Fisik
Hlm. 103-110
Dilihat sebanyak
725
Penerbit Poltekkes Semarang Jurusan TRR Semarang : Semarang.,
Edisi
JIMeD, Vol. 2 No. 1 Jan2016
Subjek
Klasifikasi
070

Lampiran Berkas

Citation
Sri Mulyati. (2016).Analisis Informasi Citra MRI Genu Potongan Aksial Antara Sekuen SHORT TAU INVERSION RECOVERY (STIR) dan Sekuen T2-Spectral Attenuation Inversion Recovery (T2-SPAIR)(JIMeD, Vol. 2 No. 1 Jan2016).Semarang:Poltekkes Semarang Jurusan TRR Semarang

Sri Mulyati.Analisis Informasi Citra MRI Genu Potongan Aksial Antara Sekuen SHORT TAU INVERSION RECOVERY (STIR) dan Sekuen T2-Spectral Attenuation Inversion Recovery (T2-SPAIR)(JIMeD, Vol. 2 No. 1 Jan2016).Semarang:Poltekkes Semarang Jurusan TRR Semarang,2016.Jurnal Ilmiah

Sri Mulyati.Analisis Informasi Citra MRI Genu Potongan Aksial Antara Sekuen SHORT TAU INVERSION RECOVERY (STIR) dan Sekuen T2-Spectral Attenuation Inversion Recovery (T2-SPAIR)(JIMeD, Vol. 2 No. 1 Jan2016).Semarang:Poltekkes Semarang Jurusan TRR Semarang,2016.Jurnal Ilmiah

Sri Mulyati.Analisis Informasi Citra MRI Genu Potongan Aksial Antara Sekuen SHORT TAU INVERSION RECOVERY (STIR) dan Sekuen T2-Spectral Attenuation Inversion Recovery (T2-SPAIR)(JIMeD, Vol. 2 No. 1 Jan2016).Semarang:Poltekkes Semarang Jurusan TRR Semarang,2016.Jurnal Ilmiah