Image of PERBANDINGAN INFORMASI ANATOMI DAN NILAI DOSIS RADIASI PADA CT STONOGRAPHY KASUS UROLITHIASIS DENGAN REKONSTRUKSI QUANTUM DENOISING SOFTWARE DAN ADAPTIVE ITERATIF DOSE REDUCTION 3D TERINTEGRASI AUTOMATIC EXPOSURE CONTROL

Skripsi D IV

PERBANDINGAN INFORMASI ANATOMI DAN NILAI DOSIS RADIASI PADA CT STONOGRAPHY KASUS UROLITHIASIS DENGAN REKONSTRUKSI QUANTUM DENOISING SOFTWARE DAN ADAPTIVE ITERATIF DOSE REDUCTION 3D TERINTEGRASI AUTOMATIC EXPOSURE CONTROL

XML

CT Stonography or Non Contrast Computed Tomography (NCCT) is the best radiological examination to diagnose urolithiasis, but the radiation dose received by the patient is quite large. Quantum Denoising Software (QDS) reconstruction and Adaptive Iterative Dose Reduction (AIDR) 3D result in better image quality and lower doses. The purpose of this study was determine differences in anatomic information and radiation dose (CTDIvol) in CT Stonography for urolithiasis cases between using QDS with AIDR 3D integrated Automatic Exposure Control (AEC) and to find out the best reconstruction.
This type of research is quantitative research with an experimental approach to the posttest-only control group design method. The study was conducted at Aisyiyah Hospital Malang. The sample consisted of 20 people who were divided into two treatment groups QDS and AIDR 3D. Assessment of anatomic information by 3 respondents. Analysis using the Mann Whitney test for anatomical information and t-test independent for radiation dose.
The results showed that there were significant differences in anatomic information (p-value 0.00 < 0.05) and CTDIvol value (p-value 0.01 < 0.05) between QDS reconstruction and AIDR. Reconstruction AIDR 3D is better in visualizing anatomic information with the highest mean rank which is 61.01 and the lowest radiation dose (CTDIvol) value with a dose reduction of 6.02 mGy or 41.7% compared to QDS reconstruction.


Informasi Detail

Pernyataan Tanggungjawab
Sri Mulyati; Dartini
Pengarang
TRIAS HARI NURSIANTO - Pengarang Utama
NIM
P1337430218140
Bahasa
Indonesia
Deskripsi Fisik
xvi+ 88 hlm.: Bibl.; 29 cm
Dilihat sebanyak
821
Penerbit Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG : Semarang.,
Edisi
Subjek
Klasifikasi
081

Lampiran Berkas

Citation
TRIAS HARI NURSIANTO. (2019).PERBANDINGAN INFORMASI ANATOMI DAN NILAI DOSIS RADIASI PADA CT STONOGRAPHY KASUS UROLITHIASIS DENGAN REKONSTRUKSI QUANTUM DENOISING SOFTWARE DAN ADAPTIVE ITERATIF DOSE REDUCTION 3D TERINTEGRASI AUTOMATIC EXPOSURE CONTROL().Semarang:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG

TRIAS HARI NURSIANTO.PERBANDINGAN INFORMASI ANATOMI DAN NILAI DOSIS RADIASI PADA CT STONOGRAPHY KASUS UROLITHIASIS DENGAN REKONSTRUKSI QUANTUM DENOISING SOFTWARE DAN ADAPTIVE ITERATIF DOSE REDUCTION 3D TERINTEGRASI AUTOMATIC EXPOSURE CONTROL().Semarang:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2019.Skripsi D IV

TRIAS HARI NURSIANTO.PERBANDINGAN INFORMASI ANATOMI DAN NILAI DOSIS RADIASI PADA CT STONOGRAPHY KASUS UROLITHIASIS DENGAN REKONSTRUKSI QUANTUM DENOISING SOFTWARE DAN ADAPTIVE ITERATIF DOSE REDUCTION 3D TERINTEGRASI AUTOMATIC EXPOSURE CONTROL().Semarang:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2019.Skripsi D IV

TRIAS HARI NURSIANTO.PERBANDINGAN INFORMASI ANATOMI DAN NILAI DOSIS RADIASI PADA CT STONOGRAPHY KASUS UROLITHIASIS DENGAN REKONSTRUKSI QUANTUM DENOISING SOFTWARE DAN ADAPTIVE ITERATIF DOSE REDUCTION 3D TERINTEGRASI AUTOMATIC EXPOSURE CONTROL().Semarang:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2019.Skripsi D IV



Dirujuk oleh 0 dokumen