Detail Cantuman

Image of STUDI ANGKA KUMAN UDARA RUANGAN
DI PUSKESMAS I PURWOKERTO UTARA
KABUPATEN BANYUMAS
TAHUN 2018

Tugas Akhir DIII

STUDI ANGKA KUMAN UDARA RUANGAN DI PUSKESMAS I PURWOKERTO UTARA KABUPATEN BANYUMAS TAHUN 2018

XML

Politeknik Kesehatan Kemenkes Semarang
Jurusan Kesehatan Lingkungan Purwokerto
Program Studi Diploma III Kesehatan Lingkungan
Karya Tulis Ilmiah, Mei 2018
Abstrak
Fitri Setyaningsih (Fitrisetiyangingsih4@gmil.com)
STUDI ANGKA KUMAN UDARA RUANGAN
DI PUSKESMAS 1 PURWOKERTO UTARA TAHUN 2018
Xvii+96 halaman : tabel, gambar, lampiran
Pusat kesehatan masyarakat atau puskesmas merupakan fasilitas pelayanan kesehatan yang menyelenggarakan upaya kesehatan masyarakat dan upaya kesehatan perseorangan tingkat pertama, dengan lebih mengutamakan upaya promontif dan preventif, untuk mencapai derajat kesehatan masyarakat yang setinggi-tingginya di wilayah kerjanya. Tujuan penelitian ini adalah megukur parameter fisik udara (suhu,kelembapan, pencahayaan), mendeskripsikan sarana sanitasi dan sarana prasarana bangunan , mendeskripsikan aktifitas pada Ruangan, dan mengukur jumlah angka kuman udara.
Penelitian ini dilakukan dengan metode deskriptif observasional yang bertujuan untuk mengetahui jumlah kuman pada Ruangan di Puskesmas I Purwokerto Utara .
Hasil penelitian menunjukan bahwa parameter suhu udara di Puskesmas 1 Purwokerto utara pada Ruang Poli gigi, Poli Lansia, Pemeriksaan Umum, Gizi dan MTBS masih ada yang belum memenuhi Syarat. rata-rata suhu ruangan 280C, Kelembapan rata-rata 45,75%, Pencahayaan rata-rata 867,5Lux, dan angka kuman udara rata-rata 285.555 CFU/m3. Sarana sanitasi yang terdapat pada ruangan seperti lantai, dinding, langit-langit, Ac.
Penelitian menyimpulkan Kondisi fisik lingkungan berupa suhu, kelembapan pencahayaan, belum memenuhi syarat. Peneliti menyarankan untuk melakukan pemeriksaan angka kuman udara secara berkala dan melakukan pengendalian angka kuman udara menggunakan alat UV countinue serta pelaksaan pengepelan (dusting) dengan menngunakan desinfektan yang intensif.
Daftar bacaan : 19 (1980 – 2017)
Kata kunci : Angka Kuman, udara, Kesehatan Lingkungan
Klasifikasi : -
iii
Health Polytechnic Of Semarang
The Departement of Environmental Health Purwokerto
Diploma Course III Environmental Health
Script Writing, May 2018
Abstrak
Fitri Setyaningsih (Fitrisetiyangingsih4@gmil.com)
STUDY THE NUMBER OF INDOOR AIRBORNE BACTERIA IN PUSKESMAS 1 PURWOKERTO NORTH OF BANYUMAS DISTRICT IN 2018
Xvii+96 halaman : tabel, gambar, lampiran
A public health center or health center is a health service facility that carries out public health efforts and individual health efforts of the first level, with priority on Promotional and preventive efforts, to achieve the highest degree of public health in its working area. The purpose of this research is Megukur physical parameters of air (temperature, humidity, lighting), Describe sanitation facilities and building infrastructure, Describe the activities on the room, and Measure the number of air germ figures.
This research was conducted by descriptive observational method that aims to know the number of germs in the room at Puskesmas I Purwokerto Utara.
The result of the research shows that the temperature parameters at Puskesmas 1 Purwokerto north on Dental Poly Room, Elderly Police, General Examination, Nutrition and MTBS still have not fulfill the requirement. average room temperature 280C, average humidity 45.75%, average illumination 867,5 Lux, and average air gap rate 285.555 CFU/ m3. Sanitary facilities in rooms such as floors, walls, ceilings, ac.
The study concluded that the physical condition of the environment in the form of temperature, humidity of lighting, not yet qualified. Researchers recommend to check the airborne germ period regularly and control the number of airborne bacteria using UV countinue and dusting by using intensive disinfectant.
Reading list : 19 (1980 - 2017) Keywords : The germ, Air, Environmental Health


Informasi Detail

Pernyataan Tanggungjawab
Tri Cahyono, SKM, M.Si
Pengarang
FITRI SETYANINGSIH - Pengarang Utama
NIM
P1337433115034
Bahasa
Indonesia
Deskripsi Fisik
-
Dilihat sebanyak
191
Penerbit Poltekkes Kemenkes Semarang : JUR.KESING PURWOKERT.,
Edisi
Subjek
Klasifikasi
NONE

Lampiran Berkas

Citation
FITRI SETYANINGSIH. (2018).STUDI ANGKA KUMAN UDARA RUANGAN DI PUSKESMAS I PURWOKERTO UTARA KABUPATEN BANYUMAS TAHUN 2018().JUR.KESING PURWOKERT:Poltekkes Kemenkes Semarang

FITRI SETYANINGSIH.STUDI ANGKA KUMAN UDARA RUANGAN DI PUSKESMAS I PURWOKERTO UTARA KABUPATEN BANYUMAS TAHUN 2018().JUR.KESING PURWOKERT:Poltekkes Kemenkes Semarang,2018.Tugas Akhir DIII

FITRI SETYANINGSIH.STUDI ANGKA KUMAN UDARA RUANGAN DI PUSKESMAS I PURWOKERTO UTARA KABUPATEN BANYUMAS TAHUN 2018().JUR.KESING PURWOKERT:Poltekkes Kemenkes Semarang,2018.Tugas Akhir DIII

FITRI SETYANINGSIH.STUDI ANGKA KUMAN UDARA RUANGAN DI PUSKESMAS I PURWOKERTO UTARA KABUPATEN BANYUMAS TAHUN 2018().JUR.KESING PURWOKERT:Poltekkes Kemenkes Semarang,2018.Tugas Akhir DIII



Dirujuk oleh 0 dokumen