Detail Cantuman

Image of ANALISA PERBEDAAN INFORMASI CITRA ANATOMI PADA PEMERIKSAAN MSCT BRAIN PADA KLINIS STROKE ISKEMIK DENGAN DAN TANPA REKONSTRUKSI SAFIRE

Skripsi D IV

ANALISA PERBEDAAN INFORMASI CITRA ANATOMI PADA PEMERIKSAAN MSCT BRAIN PADA KLINIS STROKE ISKEMIK DENGAN DAN TANPA REKONSTRUKSI SAFIRE

XML

Background : Patients with prolonged hospitalization, CT Scan examination is not performed only once for evaluation so low doses of radiation are more beneficial to the patient but may result in increased noise in the form of Quantum Mottle Artifact in the image if only using FBP standard reconstruction. The higher the noise results in decreased image quality and will cover the limits of ischemic lesions. SAFIRE software is software that uses Iterative Reconstruction (IR) technique with noise reduction as its main purpose. The purpose of this study was to determine the difference of anatomical image information and to determine which is more optimal with or without SAFIRE software on MSCT Brain examination in clinical Ischemic Stroke.
Methods : This type of research is quantitative with an experimental approach. The study used MSCT Siemens 128 slice plane at RSUD Tugurejo Semarang with 10 ischemic stroke patients with variation of SAFIRE strength 4 and without SAFIRE. The study respondents used 2 doctors of Radiology Specialists. Questionnaire results of respondents will be analyzed using statistical test Wilcoxon Sign Rank Test.
Results : Difference in anatomical image information on MSCT Brain in ischemic stroke clinics with and without SAFIRE software. The significance value of Wilcoxon test on the anatomy of substantia alba and substansia gricea, basal ganglia, ventricular system, CSF space around mesencephalon and infarct pathology was 0.000 or p value


Informasi Detail

Pernyataan Tanggungjawab
Bambang Satoto;Jeffri Ardiyanto
Pengarang
Miftakhul Noni Arifah - Pengarang Utama
NIM
P1337430214083
Bahasa
Indonesia
Deskripsi Fisik
xviii, 87 hlm. ; 29 cm
Dilihat sebanyak
1218
Penerbit Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG : POLTEKKES KEMENKES SEMARANG.,
Edisi
Subjek
Klasifikasi
081

Lampiran Berkas

Citation
Miftakhul Noni Arifah. (2018).ANALISA PERBEDAAN INFORMASI CITRA ANATOMI PADA PEMERIKSAAN MSCT BRAIN PADA KLINIS STROKE ISKEMIK DENGAN DAN TANPA REKONSTRUKSI SAFIRE().POLTEKKES KEMENKES SEMARANG:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG

Miftakhul Noni Arifah.ANALISA PERBEDAAN INFORMASI CITRA ANATOMI PADA PEMERIKSAAN MSCT BRAIN PADA KLINIS STROKE ISKEMIK DENGAN DAN TANPA REKONSTRUKSI SAFIRE().POLTEKKES KEMENKES SEMARANG:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2018.Skripsi D IV

Miftakhul Noni Arifah.ANALISA PERBEDAAN INFORMASI CITRA ANATOMI PADA PEMERIKSAAN MSCT BRAIN PADA KLINIS STROKE ISKEMIK DENGAN DAN TANPA REKONSTRUKSI SAFIRE().POLTEKKES KEMENKES SEMARANG:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2018.Skripsi D IV

Miftakhul Noni Arifah.ANALISA PERBEDAAN INFORMASI CITRA ANATOMI PADA PEMERIKSAAN MSCT BRAIN PADA KLINIS STROKE ISKEMIK DENGAN DAN TANPA REKONSTRUKSI SAFIRE().POLTEKKES KEMENKES SEMARANG:Prodi DIV T. Radiodiagnostik dan Radioterapi Semarang POLTEKKES KEMENKES SEMARANG,2018.Skripsi D IV



Dirujuk oleh 0 dokumen