ANALISIS PERBEDAAN INFORMASI CITRA ANATOMI PADA MSCT ABDOMEN DENGAN DAN TANPA SOFTWARE SAFIRE

XML

Noise is the standard deviation of matrix value (pixels). Increased noise makes image quality decreases. Decreasing image quality will bothered MSCT Abdominal results. SAFIRE is software that uses Iterative Reconstruction (IR) technique with reduction of noise as its main purpose. The purpose of this research was to determine of the difference of anatomical image information on MSCT Abdominal with and without SAFIRE and to know level strength that gives optimal image.
This research is an experimental research with static group comparison. This research was used MSCT Siemens 128 slice at RSUD Tugurejo Semarang with variation of SAFIRE and without SAFIRE. The results of this research were obtained from questionnaire from respondents on abdominal aortic organ, right lobe hepatic, portal vein, gallbladder, and colon assendens/transversum. The analysis data was done by Wilcoxon test and descriptive mean rank test.
The results of this research showed that there was a difference in anatomical image information on MSCT Abdominal with and without SAFIRE. The significance value of Wilcoxon test in abdominal aortic, right lobe hepatic, portal vein, and gallbladder is p value < 0,05. While colon assendens/transversum is p value > 0,05. Strength levels settings that can give optimal anatomical image information is S3 and S4. Abdominal aortic’s mean rank is 3,25 on S3 and S4; right lobe hepatic’s mean rank is 3,56 on S2 and S3; portal vein’s mean rank is 3,56 on S3 and S4; gallbladder’s mean rank is 3,44 on S4; and colon assendens/transversum’s mean rank is 3,50 on S3.


Informasi Detail

Pernyataan Tanggungjawab
Emi Murniati, S.ST., M.Kes , Sudiyono, S.E, M.Kes.
Pengarang
HALINDA FATMAYANTI - Pengarang Utama
NIM
P17430213057
Bahasa
Indonesia
Deskripsi Fisik
xv page + 6 halaman ada gambar dan tabel
Dilihat sebanyak
620
Penerbit Poltekkes Kemekes Semarang : POLTEKKES KEMENKES SEMARANG.,
Edisi
Subjek
Klasifikasi

Lampiran Berkas

Citation
HALINDA FATMAYANTI. (2017).ANALISIS PERBEDAAN INFORMASI CITRA ANATOMI PADA MSCT ABDOMEN DENGAN DAN TANPA SOFTWARE SAFIRE().POLTEKKES KEMENKES SEMARANG:Poltekkes Kemekes Semarang

HALINDA FATMAYANTI.ANALISIS PERBEDAAN INFORMASI CITRA ANATOMI PADA MSCT ABDOMEN DENGAN DAN TANPA SOFTWARE SAFIRE().POLTEKKES KEMENKES SEMARANG:Poltekkes Kemekes Semarang,2017.Skripsi D IV

HALINDA FATMAYANTI.ANALISIS PERBEDAAN INFORMASI CITRA ANATOMI PADA MSCT ABDOMEN DENGAN DAN TANPA SOFTWARE SAFIRE().POLTEKKES KEMENKES SEMARANG:Poltekkes Kemekes Semarang,2017.Skripsi D IV

HALINDA FATMAYANTI.ANALISIS PERBEDAAN INFORMASI CITRA ANATOMI PADA MSCT ABDOMEN DENGAN DAN TANPA SOFTWARE SAFIRE().POLTEKKES KEMENKES SEMARANG:Poltekkes Kemekes Semarang,2017.Skripsi D IV



Dirujuk oleh 0 dokumen